Model VE2

Our most popular Mass Extraction instrument. With built-in quick fill for higher throughput, handling medium sized parts is a breeze. With the VE2 you're able to test parts with tightness requirements from 1x10-4 sccs with air. The VE2 comes ready for industrial applications as well as aseptic and clean-room environments. The graphical toughscreen with real time signature graphs make it easy to operate. Assign an IP address to the instrument to enable LAN interface setup. This eliminates the risk of integrity setup and allows for remote data collection.

Request Quote

Product Usage

  • Leak Testing Under Vacuum (2 psia to Barometric Pressure)
  • Mass Extraction Tests
  • Leak Rates of 5x10<sup>-4</sup> sccs
  • Small to Medium Sized Parts
  • Package Leakage Testing
  • UL and CE Approved

Features

  • Micro-Flow sensor - The Intelligent Gas Leak Sensor (IGLS)
  • Automated vacuum test circuit
  • Touch Screen Display
  • Built in Verification Orifice (Equivalent Channel or Diameter) and Valve
  • Digital and Analog I/O Interace
  • Ethernet or Serial Interface
  • Faster Test Time
  • Stainless Steel Enclosure for Aseptic and Cleanroom Applications

All Products Ship Fully Calibrated. NO Daily Calibration Required.

  • 12"W x 12"H 12"D (Not including Connectors & Fittings)
  • Expansion Tank & Pressure Regulators are Mounted Externally

Connections, I/O & Power

Power Supply :

  • 115VAC - 60Hz
  • 220VAC - 50Hz (optional)

Pneumatic Connections:

  • Test Port and Vacuum - 3/8" Swagelok Located on Side of Instrument

Digital Inputs:

  • 5 VDC, Opto-Isolated for Start, Stop, Type, Pressure Switch, Verify

Digital Outputs: 

  • 30 VDC - 20 mA, Opto-Isolated for Pass, Fail, Clamp, Test Type, Exhaust and Custom.

Analog Outputs:

  • Single Channel, 0-5 VDC Pressure Control

RJ45 Ethernet or RS232 Serial Interface

Applicable Miro-Flow Sensors:

  • Sensor IL2-M at pressures up to 10 psig
  • Sensor IL2-C
Specifications

Product Usage

  • Leak Testing Under Vacuum (2 psia to Barometric Pressure)
  • Mass Extraction Tests
  • Leak Rates of 5x10<sup>-4</sup> sccs
  • Small to Medium Sized Parts
  • Package Leakage Testing
  • UL and CE Approved

Features

  • Micro-Flow sensor - The Intelligent Gas Leak Sensor (IGLS)
  • Automated vacuum test circuit
  • Touch Screen Display
  • Built in Verification Orifice (Equivalent Channel or Diameter) and Valve
  • Digital and Analog I/O Interace
  • Ethernet or Serial Interface
  • Faster Test Time
  • Stainless Steel Enclosure for Aseptic and Cleanroom Applications
Dimensions
  • 12"W x 12"H 12"D (Not including Connectors & Fittings)
  • Expansion Tank & Pressure Regulators are Mounted Externally
Accessories

Connections, I/O & Power

Power Supply :

  • 115VAC - 60Hz
  • 220VAC - 50Hz (optional)

Pneumatic Connections:

  • Test Port and Vacuum - 3/8" Swagelok Located on Side of Instrument

Digital Inputs:

  • 5 VDC, Opto-Isolated for Start, Stop, Type, Pressure Switch, Verify

Digital Outputs: 

  • 30 VDC - 20 mA, Opto-Isolated for Pass, Fail, Clamp, Test Type, Exhaust and Custom.

Analog Outputs:

  • Single Channel, 0-5 VDC Pressure Control

RJ45 Ethernet or RS232 Serial Interface

Applicable Miro-Flow Sensors:

  • Sensor IL2-M at pressures up to 10 psig
  • Sensor IL2-C