Model ME2

Instrument Applications:
- Leak testing under vacuum
- Slip and viscous flow regime (2 psia to barometric pressure)
- Leak Tightness from 1X10-5 sccs at 2 psia (1 µm defect size); or
- Hard vacuum - Molecular Flow (less than 0.1 psia)
- Leak Tightness from 5X10-7 sccs at 0.02 psia (0.1 µm defect size)
- Mass Extraction tests
- Medium size parts, higher throughput
- Cleanroom or industrial applications
Leak Test Simulator: Use our Leak Test Simulator to optimize your application and define your micro-flow sensor/instrument.
Available Options: Please see ATC's options chart.
Features:
- Micro-Flow Sensor - The Intelligent Gas Leak Sensor (IGLS); or
- Molecular Flow Sensor - The Intelligent Molecular Leak Sensor (IMFS)
- Automated vacuum test circuit, uniquely designed for ultra-tight leak specification
- Built in Balance and Quick Evacuation circuits
- Frontal graphical display with touch screen
- Built in Equivalent Diameter (ED)
- Digital and analog I/O Interface
- Ethernet, Serial Interface
- Stainless steel enclosure for cleanroom
- Oil-less various sizes, vacuum generation and control packages
- Optional test cart with vacuum generation and control packages
Applicable Micro-Flow Sensors (IGLS):
- Vacuum Sensor: Model IL2-M, calibrated from 2 psia (slip and viscous flow regimes)
- Hard Vacuum Sensor:Model IMFS, calibrated from 0.01 to 0.2 psia (Molecular and transitional flow regimes)
Specifications
Dimensions & Access:
- 17”W, 24”H, 19”D (Does not include connectors & fittings)
- Optional Cart Size: 28”W, 47”, 20”D
- Expansion tank, vacuum generation and control package are externally mounted on optional cart
Gases:
- Dry, clean gases: air, nitrogen
- For other gases, consult ATC, Inc.
- Digital Inputs: 5 VDC, NPN Opto-Isolated for start, stop, type, pressure
switch, verify. Digital Outputs: 30 VDC-20 mA, NPN, opto-isolated for
pass, fail, clamp, test type, exhaust and custom
Analog outputs: single channel, 0-5 VDC pressure control - Pneumatic connections:
Test Ports
Air supply: ¼” Swagelok
Vacuum: 3/8” to 1” NW
(Application dependent) - RS232 Serial Interface
- Power Supply:
115VAC-60Hz
220VAC-50Hz (optional)
Print Model ME2 - PDF (563K)
Top of Page